Equipment
▼
Dry Chemical Fill Systems
Hydrostatic Test Equipment
▼
Cylinder Dryers
Hydrostatic Test Adapters
Workbench Packages
Regulators
Cylinder Vises
Clean Agent Systems
▼
FE-36/Halotron 1
Halon 1211
HFC-227/Halon 1301
Filtration System
CO2 Transfer Pumps
Fire Hose Testers
▼
Fire Hose Tester Electric
Fire Hose Tester Pneumatic
Hose Test Adapters
Shop Equipment
▼
Air Compressors
Scales
Dust Collection Systems
Workbenches
NFPA 17/17A Service Equipment
Maintenance Kits
Product Specials
Vehicles
▼
Chevy Cutaway
▼
Combo Systems Truck
Hydro Equipment
SCBA Truck
Ford Transit T350 Cutaway
Mid/High Roof Van
▼
System Install/Service
Swap Vehicle
Full Size Cargo Van with Slides
▼
Chevy Cargo Van
Ford Low Roof Transit Van
Compact Cargo Van
Cab Chassis Vehicle
Low Roof Body
Hood Cleaning Vehicle
Trailers
Vehicle Accessories
Used Vehicles
ADX
▼
ABC Models
Purple K Models
Halon Models
ADX Parts
ADX Tools
ADX – About Us
Training
Product Manuals
Videos
General
▼
About Us
Distributors
Join Email List
Links
Privacy Policy
Contact Us
Skip to navigation
Skip to content
Getz Equipment Innovators
Search for:
Search
Menu
Home
ADX
Cart
Checkout
Contact Us
General
About Us
Distributors
Join Email List
Links
Privacy Policy
Login
My Account
Pre-Engineered Test 2021
Privacy Policy
Product Manuals
Quiz
Register
Request a Quote
Request a Quote Thanks
Shop
Training
Training Video
Vehicles
14 ft mobile service trailer
Cab Chassis Vehicle
Compact Cargo Van
Cutaway Service Vehicle
Combo Systems Truck
Hydro Equipment
SCBA Truck
Ford Transit T350 Cutaway
Full Size Cargo Van with Slides
Chevy Cargo Van
Ford Low Roof Transit Van
Hood Cleaning Vehicle
Low Roof Body
Mid/High Roof Van
Swap Vehicle
System Install/Service
Videos
Home
ADX
Cart
Checkout
Contact Us
General
About Us
Distributors
Join Email List
Links
Privacy Policy
Login
My Account
Pre-Engineered Test 2021
Privacy Policy
Product Manuals
Quiz
Register
Request a Quote
Request a Quote Thanks
Shop
Training
Training Video
Vehicles
14 ft mobile service trailer
Cab Chassis Vehicle
Compact Cargo Van
Cutaway Service Vehicle
Combo Systems Truck
Hydro Equipment
SCBA Truck
Ford Transit T350 Cutaway
Full Size Cargo Van with Slides
Chevy Cargo Van
Ford Low Roof Transit Van
Hood Cleaning Vehicle
Low Roof Body
Mid/High Roof Van
Swap Vehicle
System Install/Service
Videos
Login for Pricing
0 items
Login
Register
My Account
Checkout
Quote
Search for:
Search
Call Us Now
888-747-4389
0 items
$0.00
Equipment
Dry Chemical Fill Systems
Hydrostatic Test Equipment
Cylinder Dryers
Hydrostatic Test Adapters
Workbench Packages
Regulators
Cylinder Vises
Clean Agent Systems
FE-36/Halotron 1
Halon 1211
HFC-227/Halon 1301
Filtration System
CO2 Transfer Pumps
Fire Hose Testers
Fire Hose Tester Electric
Fire Hose Tester Pneumatic
Hose Test Adapters
Shop Equipment
Air Compressors
Scales
Dust Collection Systems
Workbenches
NFPA 17/17A Service Equipment
Maintenance Kits
Product Specials
Vehicles
Chevy Cutaway
Combo Systems Truck
Hydro Equipment
SCBA Truck
Ford Transit T350 Cutaway
Mid/High Roof Van
System Install/Service
Swap Vehicle
Full Size Cargo Van with Slides
Chevy Cargo Van
Ford Low Roof Transit Van
Compact Cargo Van
Cab Chassis Vehicle
Low Roof Body
Hood Cleaning Vehicle
Trailers
Vehicle Accessories
Used Vehicles
ADX
ABC Models
Purple K Models
Halon Models
ADX Parts
ADX Tools
ADX – About Us
Training
Product Manuals
Videos
General
About Us
Distributors
Join Email List
Links
Privacy Policy
Contact Us
Home
/
Pre-Engineered Test 2021
Pre-Engineered Test 2021
Show session ID
Load Quiz
Save Quiz
Name
Email
1.
It is the intention of NFPA 17A that its provisions be applied:
To existing facilities
To structures already approved and under construction
To installations that are existing
None of the above
None
2.
NFPA 17A states that the automatic and manual means of system actuation, must be separate and independent of one another, so:
It’s easier to install
The two cannot be confused when servicing
The failure of one will not impair the operation of the other
The manufacturer can sell more equipment
None
3.
Every kitchen fire suppression system is required to be activated both manually, & automatically, without exception?
True
False
None
4.
According to NFPA 17A (2021 Edition), exhaust fans for protected hoods, upon system actuation:
Shall be shut down
Shall continue to operate
Should continue to operate
Should be shut down
None
5.
According to Chapter 8 of NFPA 17A, there are no requirements for a technician to perform maintenance on a Pre-Engineered Wet Chemical System?
True
False
None
6.
The term “Series Detector”, refers to:
A fusible link that is at the end, and furthest away from the control cabinet
A fusible link that is nearest the control cabinet
A fusible link that is between the control cabinet, and the fusible link at the end of the line
A fusible link installed in the manual actuator line
None
7.
A fusible link is required to:
Be listed
Be painted
Be stamped with the listing symbol, manufacturer, temperature rating, & date of manufacture
Have a glass bulb like a sprinkler head
None
8.
Fusible links are required to:
Be replaced semi-annually
Be destroyed when taken out of service
Be listed as a device that detects heat
All of the above
None
9.
Manual actuators shall not require a movement of more than _______ inches, to initiate operation?
12
6
14
24
None
10.
All manufacturers have the same design requirements? (Detector & Nozzle Spacing, Number of Corner Pulleys, etc..)
True
False
None
11.
Which of the following would NOT normally be an acceptable nozzle material?
Brass
Stainless Steel
Cast Iron
Chrome Plated Brass
None
12.
How often does Ansul require that their rubber nozzle caps be replaced?
Semi-annually
Annually
Every three years
They only require replacement if damaged
None
13.
In a majority of cases, a “Tee Pulley” is only acceptable to be used on:
The manual actuator line
The detection and manual actuator lines
The manual actuator and gas valve lines
The detection, manual actuator, & gas valve lines
None
14.
A manual actuator is required to be mounted:
Outside of the protected kitchen
Between 42” & 48” above the floor
At all means of egress from the kitchen
Within 30’ of the appliances
None
15.
As per NFPA 17A, upon activation of any fire extinguishing system protecting commercial cooking operations:
The fire department shall be notified
Fuel shut-off devices shall be required to be manually reset
Only gas appliances are required to be shut down
The fresh air makeup fan shall continue to run
None
16.
NFPA 17A states all electrical wiring and equipment shall be installed in accordance with:
UL-300
NFPA 70
NFPA 72
NFPA 101
None
17.
According to NFPA 17A, manual actuators shall be a minimum distance from a protected cooking hazard, of at least:
5 ft.
25 ft.
30 ft.
No distance is specified in NFPA 17A
None
18.
What is a maintenance requirement of non-pressurized wet chemical cylinders, that is NOT a requirement of pressurized wet chemical cylinders?
That an external visual inspection for corrosion, pitting, etc.., be conducted
That it be hydrostatically tested every 12 years
That it be de-valved for verification of agent type and liquid level
That the wet chemical removed from the cylinder, for hydrotest, be discarded
None
19.
The Co2 or Nitrogen cartridges, used in an Ansul R-102 system, provide what type of gas to the agent cylinder?
Expellant
Actuation
None
20.
According to NFPA 17A, a pipe obstruction test is required to be conducted semi-annually. When does the standard require that the piping be flushed?
Annually
When the system fails the obstruction test
After any discharge
Every 5 years
None
21.
It is acceptable to use any manufacturer’s agent in an Amerex cylinder, but in an Ansul cylinder, you are only allowed to use Ansul agent.
True
False
None
22.
Wet Chemical cylinders are not subject to “Six Year Maintenance” requirements, the way that Dry Chemical cylinders are.
True
False
None
23.
On an Ansul R-102 system, the first number stamped on a system nozzle, indicates what?
The manufacturer’s part number
The number of flow points the nozzle is rated for
Where the nozzle falls in the design sequence
How many nozzles are allowed to be installed on the system
None
24.
Is the “Authority Having Jurisdiction”, allowed to modify the requirements outlined in the standard, and set their own rules for the design and operation of the system?
Yes
No
None
25.
According to NFPA 17A, the following is required upon system actuation:
The fire alarm system (if equipped), shall be activated by the system
All sources of fuel & electric power that produce heat to protected appliances, shall be shut down
Makeup air supplied internally to a protected hood, shall be shut down
All of the above
None
26.
Galvanized pipe and fittings:
Are never allowed to be used
Are only allowed when specifically listed with the system
Are only allowed if the nozzles are equipped with strainers
Are allowed when sleeved with chrome
None
27.
Which of the following is correct, if residential cooking equipment is being used, for commercial cooking operations?
NFPA 96 does NOT apply
It can only be used if acceptable to the AHJ
NFPA 96 may be applicable
Residential equipment cannot be used in this application
None
28.
Who is required to provide protection of any common exhaust ducts, used by more than one tenant?
The tenants shall share equal responsibility
The first tenant to install a system, utilizing the common exhaust duct
The building owner(s), or owner’s agent
The AHJ
None
29.
The metal grease collection container at the end of a pitched drip tray, cannot exceed what volume?
5 Gallons
2 Gallons
1 Gallons
20 Ounces
None
30.
Per NFPA 96, the distance between the grease removal device (filter) and the cooking surface, shall be not less than:
24 inches
18 inches
12 inches
48 inches
None
31.
Which of the following are required to comply with NFPA 96, when engaged in commercial cooking, with combustible media?
Fixed Concession Buildings
Tents
Mobile Food Trucks
Pavilions
All of the above
None
32.
Per NFPA 96, grease removal devices shall be mounted:
At an angle not less than 45˚
At a 45˚ angle
At a 30˚ angle
Every 24” above any protected appliances
None
33.
Per NFPA 96, high volume cooking operations require inspection for grease buildup:
Monthly
Quarterly
Semi-Annually
Annually
None
34.
The following portable fire extinguisher requirements must be met, for cooking appliance hazards involving combustible cooking media, in compliance with NFPA 96, NFPA 10, and the NFC.
a) One 1.5 Gal. (6L) Class K portable fire extinguisher located within 30’ of any commercial cooking appliance that has a potential for fire involving combustible cooking media
One 4-A: 80-B:C rated Dry Chemical fire extinguisher
One 1.5 Gal. (6L) Class K portable fire extinguisher for every four deep fat fryers with a maximum cooking media capacity of 80 pounds each
All of the above
None
35.
Class K extinguishers are listed for the purpose of being a primary fire fighting device?
True
False
None
36.
NFPA 96 states that exhaust systems shall be operated:
Whenever the establishment is actively cooking
Whenever the fresh air intake is operating
When there are no grease removal devices in place
Whenever cooking equipment is turned on
None
37.
Penetrations through a listed “Class 1” grease collection hood, must be:
Greasetight
Welded
Liquidtight
At least ¼” larger than the component penetrating it
None
38.
NFPA 96 states that with limited exceptions, solid fuel cooking appliances cannot share an exhaust hood, with other types of cooking appliances?
True
False
None
39.
According to NFPA 96, which is the correct statement, when cooking equipment has been moved?
Fire extinguishing systems shall require reevaluation where the cooking appliances are moved to perform maintenance and cleaning provided the appliances are returned to approved design location prior to cooking operations, and any disconnected fire-extinguishing system nozzles attached to the appliances are reconnected in accordance with the manufacturer's listed design manual.
Fire extinguishing systems shall not require reevaluation where the cooking appliances are moved to perform maintenance and cleaning provided the appliances are returned to approved design location prior to cooking operations, and any disconnected fire-extinguishing system nozzles attached to the appliances are reconnected in accordance with the manufacturer's listed design manual.
Fire extinguishing systems do not require reevaluation, where the cooking appliances are moved to perform maintenance, and cleaning
Movement of appliances for any reason, requires reevaluation of the system, by a qualified Technician
None
40.
Per NFPA, “Approved” means:
Acceptable to the listing agency
Acceptable to the manufacturer
Acceptable to the inspecting contractor
Acceptable to the AHJ
None
41.
As referenced in NFPA96, what term best fits the following definition: "A valve or plate within a duct for controlling draft or the flow of gases, including air"?
A Plenum
A Grease Removal Device
A Damper
None of the above
None
42.
The minimum clearance distance between limited combustible materials, and hoods, grease removal devices, exhaust fans, and/or ducts, shall be at least:
18 inches
0 inches
24 inches
3 inches
None
43.
Per NFPA 96, the distance between the exhaust fan and the fresh air intake when mounted on the same horizontal plane, shall be ________ feet at a minimum.
21.25
32.5
10
12.5
None
44.
Where openings large enough for personnel entry, are not possible in horizontal exhaust ductwork, access panel openings large enough to permit thorough cleaning shall be provided at _______ feet intervals.
12
6
20
10
None
45.
NFPA 70 (National Electrical Code), states that power limited fire alarm circuits can share the same raceway with which of the following, under normal circumstances?
Power Conductors
Lighting Conductors
Class 2 Control & Signaling Circuits
Non-Power-Limited Fire Alarm Circuits
None
46.
The grease removal devices for solid fuel cooking appliances shall have:
Self-cleaning capabilities
Spark arresters
A larger surface area than conventional grease removal devices
Greater air-flow capacity
None
47.
Deep fat fryers shall be installed with at least a ________ inch space between the fryer, and surface flames from adjacent cooking equipment.
24
12
16
8
None
48.
Back shelves are allowed to be installed after the initial installation, without reevaluation of the design layout?
True
False
None
1 out of 48
Time's up
Quick Links
Home
Contact Us
About Us
Privacy Policy
Distributors
Links
Join Email List
Address
Getz Equipment Innovators
2320 Lakecrest Dr
Pekin, IL 61554
(888) 747-4389
(309) 495-0625
Choose Preferred Language
GETZ EQUIPMENT INNOVATORS – 2025